Wednesday, May 16, 2007

How SMART is that tunnel?


So Malaysia finally soft-launched the first of its kind, the Stormwater Management And Road Tunnel (SMART) on 14 May 2007 (Monday). I didn't have any inkling that it was open until I saw a steady stream of cars exiting the tunnel at Jalan Tun Razak the day after. So that was the cause of the congestion and slow-moving traffic all the way from the Seremban Highway! Today was no better and I heard a motorist on the radio yesterday evening complaining that she was stuck in a traffic jam INSIDE the tunnel. Is anyone thinking of Sylvester Stallone in Daylight yet?

If I were a motorist considering using the SMART tunnel and I encountered said bottleneck to exit the tunnel after paying a high toll fee (although that has yet to be set), I would think twice about using it. Pay toll already also still meet traffic jam! But it could be a case of "new toilets" by the Malaysian public. Anything new must try first and while it's still damage-free. Then, after a while the Malaysian mentality of "use while free, don't use if you have to pay" will kick in, and the SMART tunnel should be relatively traffic free once toll collection starts. Would you pay RM 3 - 4 (fake estimated toll) to save 20 minutes of time on a daily basis? Me, a normal wage earner, would not unless I was really pressed for time and desperate.

OK, so that's about the jam and the toll. But my overactive imagination tells me this... this SMART tunnel is supposed to be both an access road for traffic as well as a diversion for excess floodwater as part of upgrading KL drainage system. Rest assured, people, that the designers and builders of the SMART tunnel took this into consideration and built THREE different levels into the same tunnel - two for traffic, one for water. So both won't meet at say some point in the middle of the tunnel. Sounds safe, right? But what worries me is this... How SMART are the personnel manning the SMART tunnel? I can just imagine Ah Beng, Ali, Muthu or Jack sipping teh tarik and upon hearing thunderstorm, flicks a switch to activate the water tunnel but... you get my drift? *grin*

Note: This post is intended in jest and does not mean and disrespect to the marvel of engineering and billions that went into the making of this tunnel and the people manning it. I am sure that there are adequate safety controls implemented. *grin*

18 spins:

kyh said...

oh rupa2nya this is smart tunnel. HAAAA!!! by looking at the design of it, sure it's one feat of engineering. :)

rainbow angeles said...

No yet read but from the way I see, it's not so smart, rite?

Thank gawd I don't work in the city!

Anonymous said...

i trust the people who built it but not the people who are operating it. Skali no maintenance die man!

Winn said...

ppl who use that tunnel are 'SMART'.......haaaaaa!

msia boleh. yeah.
but thank to smart tunnel, it did help to ease a bit of the traffic in kl.......temporary

narrowband said...

Yah I wonder what happens too if the person managing it is some incompetent oaf.

And a traffic jam, inside the tunnel, huh? It's so narrow and in case anything happens, it's going to be a big problem. The tunnel in Daylight was so wide and high.

I really hope the speed limit is adhered to and people don't do stupid stuff in there. By the way, there's even a video, taken by melvinf while using the tunnel. Experience the tunnel first-hand, here.

Let's give it some time and we'll see if the tunnel will be helpful. Especially since Samy Vellu already said the toll is definitely going to be very expensive.

zewt said...

hahaha... "new toilets"... san si hang!

didnt know you actually need to maintain the tunnel in order to control the water flow. if that is true... i think our malaysian standard of maintenance will one day cause god to take some action resulting in .... "ACT OF GOD"... you know what i mean? sam jiu ler...

Simple American said...

So kena fins for your car?

I hate tunnels. And making tunnels in a place that floods. Just does not seem bright. Oh well. Engineers have done great things. Hope this is great for y'all.

L B said...

Yeah, I really did think Sylvester Stallone while reading this.. Are Mat Rempits allowed in?

may said...

this actually looks ominous... hmmm, I think I'll stick to above-ground travels!

Ehon said...

I agree with Ah May!! Kekekeke.

I thought apa so smart about the tunnel! Now I know. Pfft! Though whoever use that tunnel must be smart ppl too. Chemistry rule mar - "like dissolves like". Hahahaha! :P

Smart tunnel, smart engineers, maintainers er... well.. MALAYSIA BOLEH! MALAYSIA BO LEH. (don have ler) Mana ada?

cutiepie said...

the toughest part would be to educate our drivers to drive 'SMARTLY'

Anonymous said...

jie jie rinnah

thank you for visiting my blog ... hugs hugs

Anonymous said...

Would we hear less of Jalan Tun Razak being highly traffic-congested then?
I would like to try this SMART tunnel someday though. See what the hooha is all about.

rinnah said...

kyh: 5 hugs for your amazing feat of chupping nearly every post I write!!!

**********
angel: 3 smart hugs for you!!

So lucky you don't work in the city!

**********
parisb: 1 well-maintained hug for you!

That's a very valid point! I agree!

**********
winn: Did it ease traffic in KL? Where I work it aggravated the situation a bit more. Maybe the people are not used to the traffic system yet...

**********
narrowband: Hehehe... let's hope those managing the tunnel are truly SMART!

The video's very informative! ;o)

I plan to take a drive thru the tunnel on a weekend before they impose a toll! New toilet mah... Ekekekeke!

**********
zewt: Yaya... new toilets. *grin*

Let's hope it will never come to that "Act of God"... because our govt doesn't sam jiu one... but waitaminute... isn't this another Semi Value project? Egads!

**********
simple american: The tunnel itself is fine, but the thought of travelling in a space together with water gives me the shivers!

**********
l b: LOL! Mat Rempits are not allowed in and the speed limit is 60kph!

**********
may: This tunnel is definitely not for those with claustrophobia...

**********
ehon: LOL! Malaysia bo leh... good one!

**********
cutiepie: That's another excellent point... I wonder how many drivers will actually stick to the 60kph speed limit!

**********
misha: Thank you dear! *hugs*

fishtail said...

One fine day when while it is still free to use, I'll take my car for a ride through the tunnel, and that's going to be it. Have no intention of paying something like Rm4 toll to use it later.

rinnah said...

fishtail: That's what I intend to do too. Better experience it now while it's free, eh? I hope it won't become a white elephant once they implement the toll.

Anonymous said...

I will start with this strong statement: The method of operation for the SMART tunnel that I have developed below provides the best possibility to minimize traffic interuption flowing in and out of the SMART tunnel. If 50 ARI (See below) design spec was followed, balance of probability suggests that the motorways of the tunnel shall not be interrupted MORE than two twice in 50 years. ARI stands for Average Recurrence Interval in years.

I’m NOT representing any party that has the authority to manage and operate SMART tunnel. I’m only an ordinary citizen who has a “gifted” knowledge to understand “extremely well” the operation and management of this kind of system.

Before I go further please understand the most important design specifications of this tunnel taken from the information given by the project’s proponent. Relevant design specification

1. Storm water design = 50 ARI. It means that the system is sized to deal with the biggest storm water/flash flood in 50 years.

2. Storm water retention capability = 3,000,000m3 that flows in 4 hours, or 208m3/s of localized rainfall that falls in 4 hours. (Assuming the storm duration is 4 hours)

Break down retention volume

a) Intake retention pond Kampong Beremban + Outlet retention pond Taman Desa + SMART tunnel (Excluding motorways) = 2,750,000m3

b) Motorways = 250,000m3

c) Total retention capability, assuming Taman Desa outlet (tunnel outlet) cannot discharging due to flow bottle at downstream has been reached (worst case scenario is assumed) =3,000,000m3

At glance, from a), b) and c) above it is obvious that we can spare motorways from participating in flood control operation for almost at all times without experiencing significant reduction on the overall SMART tunnel storm water retention capability. This is true since the motorways represent only 8% of the total retention capability of the SMART system.

1. Overall operation overview

Sungai Kelang passes a few critical flood plains in KL. These flood plains are getting flooded fairly easy during high river flow of Sungai Kelang.

When there is a heavy rainfall upstream from KL, Sungai Kelang water level in KL will eventually increase after a few hours, due to “the distance” factor. The volume of water associated with this rainfall may not high enough to flood the critical flood plains in KL since it occupies vast area along the river stretch from upstream to KL. However, more often, it is sufficient to reduce flood control capability of Sungai Kelang within the KL areas.

Assuming when Sungai Kelang water level has almost reached the top of its bank, then it follows by localized heavy thunder storm (Storm water). This storm carries the highest amount of water in 4 hours over the last 50 years, with the amount of 3,000,000 m3 (208m3/s). What will happen then? Answer: Water level will rise above its bank. Thus, flash flood starts to occur at the flood prone areas.

We can prevent such flood if we can divert up to the maximum of 3,000,000 m3 of storm water to a man made temporary storage. We hold firm this water until the rainfall stops and the water level downstream the tunnel’s outlet has gone down. Then we release it slowly and safely so that there is no area will be flooded.

This is exactly what the SMART tunnel should do. It was designed more towards to "hold" the storm water temporarily rather than to divert it, as many people think. This statement is based on the fact the tunnel outlet (Sungai Kerayung) is too small to take the design flood flow from Sungai Kelang, which is expected to be around 210m3/s (Average flow =50m3/s). In this case, diverting the flow from Sungai Kelang to Sungai Kerayung might end up with even bigger flood around Sungai Kerayung.

I have some problems to understand why the flow of traffics to the SMART tunnel interrupted so frequently. Based on the design specs of this tunnel, anything more than two interuptions in 50 years has to be explained since benefit of the doubt covers up to 2 interruptions only.

I don't know what goes wrong but I know how to make it right. See my proposed operating methodology.

The optimum operating schemes for the SMART Tunnel

We devide the operation into three stages- This is similar to the proposed scheme by the SMART management, however, detail operation at each stage may not similar with the current operation.

Stage 1: Normal storm water that has flow intensity 2,750,000m3 or less in 4 hours

Stage 2: Emergency operation for storm water that has intensity between 2,750,000 and 3,000,000m3 in 4 hours

Stage 3: Above the design storm water that has intensity above 3,000,000m3 in 4 hours.


Stage 1: Normal Operation- Storm water is less that the design value (Up to 2,750,000 m3 in 4 hours)

Storm water shall be allowed to take its natural path, i.e. Sungai Kelang, if its amount is less than a certain limit. The limit shall be set based on flood level (FL_Beremban) at Kampung Beremban’s intake (Sungai Kelang river bank’s side). The flood level is defined as the maximum allowable water level elevation, that, if it is not violated, no flood will occur at the protected flood plains downstream.

When this limit is reached, then the protected flood plains are under flood risk. Thus, the excess river flow upstream from flood plains, i.e. at Kampung Beremban shall be diverted to the tunnel for retention. This action will reduce the flow to the protected flood plains. As a result flash flood will not occur.

At this stage, the sub operational objective is to maintain FL_Beremban constant. This sub objective is achieved by means of controlling the opening of the intake gate Kampung Beremban. The main idea is to match the excess storm water to the filling rate of the tunnel. By the same time water levels at the protected flood plain areas downstream are kept constant below the flood level.

There should be no attend to be done to reduce FL_Beremban. By doing so, some space of the SMART retention volume will be occupied by “unharmed” storm water. This is counter productive since up to this time we have yet known how big the size of storm water is going to be. Thus, we need all the available space to deal with the “harmed” one.

The amount of storm water that will be kept for retention, says in 4 hours is random in nature. It could be any value between 0 to 2,750,000m3. In this case, if the design of the motorways is really “safe” and water tight, then there is no need to close down the motorways. This is because without the volume provided by the motorways (250,000m3) the desired storm water retention capability of 2,750,000m3 is more than enough to be used for storm water retention most of the time.

Can we be caught off guard by flooding the motorways while an innocence man traps inside the motorways space when the actual storm water is greater than 2,750,000m3? The answer is that, it should not be the case since we can choose for not utilizing this space. Just close down the intake gate Kampung Beremban. Keep the water tight doors of the motorways closed. Thus, no additional water will enter the tunnel and no water will enter the motorways.

However, this means we have decided to divert minor flood flow up to an additional of 250,000m3 in 4 hours (17.4m3/s) that we are in position to take it in the first place. The rational of this decision is that, it is better to flood the protected flood plains (surface flood) rather than to flood the motorways (tunnel flood) if we are not sure that the motorways have been fully evacuated.

Filling up volume up to 2,750,000m3 of the tunnel, by design, will not affect the space that has been allocated for the motorways. Therefore, there is no need to stop the traffics. Statistically, as per design data there are at the average of 11 times a 4-hour storm water fall below this amount annually. There is only one that a 4-hour storm water violates this amount in 50 years. Thus, we can keep the motorways “Business As Usual” or BAU while the remaining volume of the tunnel is used to mitigate flood.

Stage 2. Emergency operation - Storm water is between 2,750,000 and 3,000,000m3 in 4 hours

How do we know that we have to move to this stage? If the tunnel has been filled up to says 2,500,000m3 at filling rate of 208m3/s (Design peak flow of the storm water) but FL_Beremban has yet shown any tendency to go down. This indicates high flow is sustained. We need to engage Stage 2.

Evacuation plan has to be activated when the SMART tunnel has been filled says at 2,500,000m3, or 250,000m3 before the space for the motorways has to be utilized too. Taking the maximum allowable filling rate of 250m3/s (Slightly above the average design flood of 208m3/s in 4 hours), it takes exactly 1000 additional seconds (17minutes) to fill up the tunnel with additional water of 250,000m3. This is sufficient time to evacuate all traffics in the motorways minus emergency evacuation, taking the average speed of the traffics is 60km/h and the total distance between the entry and exit point is 4km. We need about 4 minutes to travel the entire distance of the tunnel under normal condition (no breakdown). Lead time for evacuation and Emergency Response Plan (ERP) shall consider the worst case scenario that traffic movement may not be as smooth as expected. We leave to the management of the system to come up with this one.

Filling up motorways shall be done from bottom to top (outlet to inlet). There are two reasons for this suggestion: 1) If anybody get traps in the motorways without SMART operator’s knowledge, he or she still has a great chance to survive by driving up to the tunnel inlet, or trying to SOS the operator. The fact is that the tunnel inlet is located at higher elevation than the outlet. Filling up the motorways may take roughly about 1000 seconds, of 17 minutes. Filling up the tunnel from inlet provides almost no chance for he or she to survive (2) Natural way to vent the air out of motorways to prevent air lock. Air lock can cause the tunnel to vibrate badly. It is possible this vibration will cause the tunnel to collapse. Filling from top down cannot guarantee the air lock scenario may not happen. However, it is true that the operation scheme can be designed to prevent such scenario from occuring by means of mechanical and control system interlocking.

Statistically, scenario in stage 2 is expected to occur at most twice in 50 years.

Stage 3: Storm water is greater than the design value

The retention capability of 3,000,000m3, including the space for motorways has been filled completely. But yet FL_Beremban doesn’t seem to go down. The design limit for retention capability of the tunnel has already been reached. We are entering the difficult scenario. We should have Emergency Response Plan (ERP) long before reaching this stage. I will show the important and critical operational issues only. Complete ERP will not be discussed.

There are two options that the SMART tunnel can be used for flood mitigation. We call them A) passive operation and B) pro active operation.

A) Passive operation

It is as simple as closing down intake gate Kampung Beremban. The SMART tunnel, now, takes it natural stand. It does not participate in flood mitigation in any way other than holding 3,000,000m3 of the storm water. Flood plains at downstream have lost their savior. They are on their own to face the impending flood.

Will it going to be any disastrous legal action taken by the affected parties, aftermath? It depends on written agreement between the SMART management and the stake holders. In this case, stake holders are the flood victims. As far as scientific and physical point of view, flood victims cannot win their case in the court of law. This is because nobody on earth is expected to have the ability to prevent natural disaster. Flood is one of the recognized natural disasters.

When I explain to my friends about this subject, one of the popular questions is, “Why the design engineers choose not to take any amount of storm water?” Actually, we cannot design this kind of system to take any amount of storm water. We can decide the amount that we want, but not any amount. The amount of design storm water is associated with design ARI. For example,

30 ARI is equivalent to 2,750,000m3 of storm water in 4 hours (Example only- may not be numerically accurate)

50 ARI is equivalent to 3,000,000m3 of storm water in 4 hours. ( The design value)

2500 ARI is equivalent to 6,000,000m3 of storm water in 4 hours (Example only-may not be numerically accurate)

Probable Maximum Storm (PMS) > 10000 ARI is equivalent to 18,000,000 m3 of storm water in 4 hours. (Example only-may not be numerically accurate)

It is normal to choose any value between 50 to 200ARI for storm water management depends upon the desired risks of the protected flood plains can effort to take. Note that the lower the risk, the higher the design cost. For example if we choose to design according to 2500 ARI, then we need to design the second SMART tunnel, identical to the current one. Then the capital cost will be two times higher. The chance is, in fact >75% chance that 2500 ARI storm water may strike 625years or longer from now! If we have the second SMART tunnel, then, what we are going to do with it for the first 624 years?

B) Pro active operation

This operation may be the most complex one. It may lead to legal action aftermath unless the Standard Operating Procedure (SOP) has been approved by relevant authorities such as JPS, Home Minister, Datuk Bandar’s Office and the Parliament.

We still have the scenario that extremely high river flow flowing to the critical flood plains in KL. The SMART tunnel has been paralyzed while holding 3,000,000m3 of storm water over the last 4 hours. The river flow may be as high as 400m3/s. How long this high flow is going to last? We have yet to know.

What the SMART tunnel could do is trying to divert a portion of the water from Sungai Kelang (inlet) to Sungai Kerayung (outlet Taman Desa). Says we chose 100m3/s. Then flood flow to the protected flood plains downstream after intake Kampung Beremban becomes 300m3/s instead of 400m3/s. If A) approach is engaged, then the flow will be 400m3/s. All river flow will be passed to Kampung Beremban downstream.

The SMART tunnel changes it function from retention to diversion. However, SOP for effective operation shall be done based on which downstream has higher priority to be protected from flood. We have two areas namely, 1) Sungai Kelang downstream 2) Sungai Kerayung downstream.

As mentioned above, it is extremely important to resolve potential legal conflict since the SMART tunnel does not take natural stand. To a certain extent, it decides which areas to be flooded and by how much. This is the tricky part. Poor handling, the management of the SMART tunnel may be challenged in court of law.

If I was allowed to reccomend, go for A) above if Stage 3 operation has to be activated.

Statistically, scenario in Stage 3 may happen once in 50 years or longer. It depends on the level flow intensity and duration. See ARI abaove.

The good news is the possiblity to happen is as small as 1%. The bad news is the possibility is real. As
Murphy's law says " Things that could go wrong will go wrong"

Thank you.

Anonymous said...

I love your blog.. very nice colors & theme. Did you design this website yourself or did you hire someone
to do it for you? Plz reply as I'm looking to create my own blog and would like to know where u got this from. many thanks

Also visit my homepage :: microsoft registry cleaner